Notes after the end of heating

2020-3-25 14:59:58 visits Sort:Technical Information

1、Dont dismantle the heating system without permission

Heating users do not disassemble heating facilities, stop heating, heating companies will carry out full water maintenance of the heating network, heating facilities have been water, once private demolition, it is easy to cause flooding.

2、When the heating is off, close the water supply and return valves in your home

Once the heating is finished, the main valve of the water supply pipe and backwater pipe should be closed in time Second, it can prevent the new heating season before the arrival of water pressure test because no one in the home accident leakage, can not be dealt with in time and other problems.

3、After the ground heating pipe to do full water maintenance

After the end of heating, floor heating users do not put the water in the heating pipe. The water in the heating pipe is soft water, can effectively isolate air into the heating system and pipes, which can extend the life of heating facilities and heating pipes.

4、Check whether the joint of the heating pipe is leaking

As a result of thermal expansion and cold shrinkage, after the end of heating, heating pipe interface may appear water leakage. Just out of heat, users should pay attention to check their heating pipe interface whether there is loose or leakage, once found leakage to timely professional maintenance.

5、Ground heating users need to carry out ground heating pipeline cleaning

During the heating process, the heating temperature of the neighbor's house is normal, while the heating temperature of the own house is not ideal. Then, after the heating is over, the floor heating user can find a professional to clean the floor heating pipes in the house, ensure the ground heating pipeline water smooth, normal heat dissipation. And after the end of heating, heating users to clean the heating filter screen in a timely manner.

6、Timely reflect the heating period

Encounter the whole building or the whole unit is not hot“Low-temperature dead angle” problem, the main pipeline or unit riser aging, serious leakage and other problems, heating users to actively reflect the situation. The heating company will carry on the repair transformation according to the user to reflect the situation in the summer, in order to next heating season use.

7、Matters needing attention of heat metering users

After heating, the heat metering users should protect their own heat meters and temperature control devices in the pipeline well to prevent damage. Wireless indoor temperature control panel heat metering users need to remove the panel battery, to prevent non-heating season due to battery leakage caused by indoor temperature control panel motherboard corrosion, affect panel service life.